01 / SHARED SPACESCommunal health & safety risk assessment+
Assess foreseeable risks in areas under management: slips and trips, stairs and handrails, lighting, glazing, access, bin stores, car parks and contractor activities. Consider who may be harmed, existing precautions and further controls.
Review: set a proportionate programme and revisit it after material changes, incidents or signs that controls are ineffective. There is no single annual certificate that covers every building and every risk.
HSE: assessing and controlling risk ↗
02 / BUILDING MATERIALSAsbestos assessment, register & management plan+
The duty to manage asbestos covers common parts of multi-occupancy residential buildings. Establish whether asbestos-containing materials may be present, where they are and their condition, using suitable survey information where needed.
What follows: maintain a register and management plan, monitor material condition and share relevant information before contractors start. Review the plan every 12 months or sooner if needed. Refurbishment or demolition can require a different survey before work begins; a management survey is not automatically sufficient.
HSE: the duty to manage asbestos ↗
03 / WATER HYGIENELegionella risk assessment+
Assess risks in the water systems for which the client has responsibility. Shared storage tanks, communal hot-water systems and little-used outlets can require more involved controls than simple, frequently used domestic systems.
What follows: implement monitoring, temperature controls, flushing or other measures identified by the assessment. Review when systems or circumstances change and at appropriate intervals. Routine sampling and an annual “Legionella certificate” are not universally required.
HSE: understanding Legionella risks ↗
04 / COMMUNAL ELECTRICSElectrical installation inspection & testing+
Communal wiring, lighting, distribution boards and supplies to shared equipment need appropriate inspection and maintenance. A competent electrical contractor can assess condition, provide an Electrical Installation Condition Report (EICR) and advise on remedial work and the next inspection.
Important distinction: the rented-home electrical safety regulations do not apply to communal areas. Do not assume their five-year rule is the legal rule for all shared installations. Set a suitable programme using condition, use, applicable standards and professional advice.
GOV.UK: electrical safety and communal areas ↗
05 / LIFTSLOLER examinations & lift servicing+
Lift maintenance and a thorough examination serve different purposes. Servicing does not replace examination by a competent person.
Typical interval: where LOLER applies, lifts carrying people require thorough examination at least every six months, or in accordance with a competent person's examination scheme. Other passenger lifts still need appropriate safety arrangements; confirm the applicable regime with a specialist.
HSE: passenger lift responsibilities ↗
06 / SITE-SPECIFIC EQUIPMENTPowered gates, barriers & other shared assets+
Powered gates and barriers need assessment of crushing, trapping and impact risks, alongside maintenance and safety checks appropriate to their design and use.
Beyond the entrance: identify other assets that may need specialist attention, such as communal plant, play equipment, trees, roof access and work-at-height arrangements. Set requirements individually; not every assessment applies to every block.
HSE: powered gate safety ↗